ELEJG للتكنولوجيا الكهربائية
الصفحة الرئيسية/المنتجات/3 phase 4 wire over and under voltage protector JGGQ-80
الصورة 0
الصورة 1
الصورة المصغرة 0
الصورة المصغرة 1
3 phase 4 wire over and under voltage protector JGGQ-80
3 phase 4 wire over-under-voltage protector is an upgrade from the ordinary type of product, product features: low power consumption, long life, precise control, phase loss protection, lack of zero line protection, maximum short-circuit limiting current 3000A, software control humanization, and clear indication with Led light, the product is powered on for the first time under normal conditions of the power supply closing time is 6 seconds, when the line occurs over-undervoltage, lack of phase and other faults, when the power supply turns normal, the closing time is 40 seconds, this design saves too much time to wait when the power grid is in the power failure.
TypeJGGQ-63/3P+N
Current specifications 32,40,50,63,80A
Over voltage AC270±5V
Under voltage AC170±5V
Introduction
3 phase 4 wire over and under voltage protector

JGGQ-80/3P+N 3 phase 4 wire over and under voltage protector It is an upgrade from the ordinary type of product, product technical characteristics: low power consumption, long life, precise control, lack of phase protection, lack of zero line protection, maximum short-circuit limit current of 3000A, software control of humanization, and clear indication with Led light, the product is powered on for the first time under normal conditions of power supply closing time of 5 seconds, when the line occurs undervoltage, lack of phase and other faults, when the power supply turns normal, the closing time is 20 seconds, this design saves too much time to wait when the power grid is out of power.

The three-phase four-wireSelf-resettable over/undervoltage protectorIt has the functions of phase loss, zero loss, overvoltage and undervoltage protection, and is often used in three-phase four-wire distribution lines and photovoltaic power generation combiner boxes.

The main technical parameters

1. Rated current: 32A, 40A, 50A, 63A, 80A

2. Working voltage: AC230V, 50Hz (phase line to neutral line working mode)

3. Overvoltage protection value: AC270V ±5V (phase to zero)

4. Undervoltage protection value: AC170V ±5V (phase to zero)

5. First power-on closing time: 5 seconds

6. Reset time after failure: 20 seconds

7. Action time: 0.1 seconds

8. The highest is possiblewithstandAC450V overvoltage(phase to zero)。

Implementation standards

 

The appearance of the size(3 phase 4 wire over and under voltage protector)
تواصل معنا
راسلنا عبر البريد الإلكتروني مع أي أسئلة أو استفسارات أو استخدم بيانات الاتصال الخاصة بنا. يسعدنا الرد على أسئلتك.
الموضوع : 3 phase 4 wire over and under voltage protector JGGQ-80
请在浏览器中启用JavaScript来完成此表单。
المنتجات ذات الصلة
×

اترك رسالة

请在浏览器中启用JavaScript来完成此表单。

اترك رسالة

请在浏览器中启用JavaScript来完成此表单。

احصل على حل معدات الليزر الخاص بك

请在浏览器中启用JavaScript来完成此表单。