Arc Fault Detection Devices JGAFDD-63
Arc Fault Detection Devices (AFDD ): hereinafter referred to as the protector, effectively detects the fault arc in the access line, including the fault parallel arc and the fault series arc, and when the fault arc that causes fire is detected in the line, the power off function can be carried out to achieve the purpose of early warning of fire. The fault arc protector is suitable for electrical circuits of 10KW and below in industrial and civil buildings
TypeJGAFDD-63
Current specifications 63A(1~63A)
Working voltage AC230V
Introduction
3 phase 4 wire over and under voltage protector

JGGQ-80/3P+N 3 phase 4 wire over and under voltage protector It is an upgrade from the ordinary type of product, product technical characteristics: low power consumption, long life, precise control, lack of phase protection, lack of zero line protection, maximum short-circuit limit current of 3000A, software control of humanization, and clear indication with Led light, the product is powered on for the first time under normal conditions of power supply closing time of 5 seconds, when the line occurs undervoltage, lack of phase and other faults, when the power supply turns normal, the closing time is 20 seconds, this design saves too much time to wait when the power grid is out of power.

The three-phase four-wireSelf-resettable over/undervoltage protectorIt has the functions of phase loss, zero loss, overvoltage and undervoltage protection, and is often used in three-phase four-wire distribution lines and photovoltaic power generation combiner boxes.

The main technical parameters

1. Rated current: 32A, 40A, 50A, 63A, 80A

2. Working voltage: AC230V, 50Hz (phase line to neutral line working mode)

3. Overvoltage protection value: AC270V ±5V (phase to zero)

4. Undervoltage protection value: AC170V ±5V (phase to zero)

5. First power-on closing time: 5 seconds

6. Reset time after failure: 20 seconds

7. Action time: 0.1 seconds

8. The highest is possiblewithstandAC450V overvoltage(phase to zero)。

Implementation standards

 

The appearance of the size(3 phase 4 wire over and under voltage protector)
GET IN TOUCH
Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.
Subject : Arc Fault Detection Devices JGAFDD-63
请在浏览器中启用JavaScript来完成此表单。
Related Products
×

Leave A Message

请在浏览器中启用JavaScript来完成此表单。

Leave A Message

请在浏览器中启用JavaScript来完成此表单。

Get Your Laser Equipment Solution

请在浏览器中启用JavaScript来完成此表单。