ELEJG Elektrische Technik
Startseite/Produkte/Automatic reset overvoltage and undervoltage protector JGGQ-63
Bild 0
Bild 1
Vorschaubild 0
Vorschaubild 1
Über- und Unterspannungsschutz mit automatischer Rückstellung JGGQ-63
JGGQ-63 Automatic reset overvoltage and undervoltage protector adopts the control circuit with high-speed micro-low-power processor as the core, magnetic latching relay as the main circuit, and modularized standard design, when the power supply line appears overvoltage and undervoltage, the protector can quickly and safely cut off the circuit under the continuous high-voltage impact to avoid the occurrence of accidents caused by abnormal voltage sent to the terminal electrical appliances, and when the voltage returns to normal values, the protector will automatically turn on the circuit within the specified time to ensure the normal operation of the terminal appliances in the unattended situation.
Rated current32A, 40A, 50A, 63A
Working voltageAC230V, 50Hz
Overvoltage protection valueAC270V ±5V
Undervoltage protection valueAC170V ±5V
Reset time after failure20 seconds
Action time0.2 seconds
Einführung

JGGQ-63 Automatic reset overvoltage and undervoltage protector When the power supply line has overvoltage and undervoltage, the protector can quickly and safely cut off the circuit under the continuous high-voltage impact to avoid the occurrence of accidents caused by abnormal voltage sent to the terminal electrical appliances, and when the voltage returns to normal values, the protector will automatically turn on the circuit within the specified time to ensure the normal operation of the terminal electrical appliances in the unattended situation.

Characteristics and use environment

1. When the single-phase line undervoltage occurs, cut off the line, and the single-phase line voltage will return to normal and automatically reset and connect the line after the delay, without manual operation.

2. When there is transient or transient overvoltage in the line, the protector will not malfunction.

3. When the voltage of the line is unstable due to faults such as false contacts, or when the power is suddenly cut off and the call suddenly comes, the protector is not connected to the line.

4. When the line fault voltage is the highest, the protector itself will not be damaged.

5. Withstand impulse voltage: 4kV (in line with the safety standards of Class III electrical appliances).

6. Ambient temperature: -25°C~40°C, relative humidity: 10%~90%, altitude not exceeding 2500 meters, and the place of use should have rainproof facilities.

Third, the main technical parameters

1. Rated current: 32A, 40A, 50A, 63A

2. Working voltage: AC230V, 50Hz

3. Overvoltage protection value: AC270V ±5V

4. Undervoltage protection value: AC170V ±5V

5. Reset time after failure: 20 seconds

6. Action time: 0.2 seconds

7. The highest is possiblewithstandAC380V overvoltage.

Fourth, the implementation of standards

JGJ242-2011 Code für die elektrische Planung von Wohngebäuden

JGJ/T16-2008

GJBT-672 Standardatlas für die elektrische Planung und Konstruktion von Wohngebäuden

GB/T68895.10-2001

Erfüllt die Sicherheitsstandards für Elektrogeräte der Klasse III

JB/T12762-2015 《Over Voltage And Under Voltage Protective Device With Auto-Reclosing Function(OUPA)》

Fifth, the use of size

KONTAKTIEREN SIE UNS
Schicken Sie uns eine E-Mail mit Ihren Fragen oder Anfragen oder nutzen Sie unsere Kontaktdaten. Wir beantworten gerne Ihre Fragen.
Thema : Über- und Unterspannungsschutz mit automatischer Rückstellung JGGQ-63
请在浏览器中启用JavaScript来完成此表单。
Verwandte Produkte
×

Hinterlassen Sie eine Nachricht

请在浏览器中启用JavaScript来完成此表单。

Hinterlassen Sie eine Nachricht

请在浏览器中启用JavaScript来完成此表单。

Holen Sie sich Ihre Laserausrüstungslösung

请在浏览器中启用JavaScript来完成此表单。